Skip to content

Runbook

Operation held

Operation
Approved, but Executed=Unknown and a value in BLOCKED. Or Executed=False with RolloutRefused.
Claim
A value in BLOCKED, and no operation exists.
Alert
PkMetalOperationBlocked: an approved operation did not start for one hour, for a reason other than OperationQueued or OutsideMaintenanceWindow. PkMetalApprovalWaiting: an operation waits more than one day for approval.

Nothing happened to the machine. Most holds end by themselves.

Read the BLOCKED value and the note line in pk-metal status. Then find it in the table.

Reason Why What to do
AwaitingApproval Nobody approved it Approve, hold, retry and abort
OperationQueued Another operation runs on the same Host Wait. One operation at a time for each Host.
OutsideMaintenanceWindow A window covers the Host and it is not open Wait, or set metal.platform-kit.org/ignore-window to <username>: <reason>. See Use maintenance windows. If the message says "none of them opens again" or "cannot read", no window opens: correct the window.
ClusterDisruption Another control plane is down, or etcd is not healthy without this one Wait. To repair a broken etcd, set metal.platform-kit.org/override-cluster-guard to <username>: <reason>.
SelfDisruption The step would reboot a machine that the operator runs on Move the operator, or set metal.platform-kit.org/allow-self-disruption on the Host. See Self-protection.
HeldByUser The claim has metal.platform-kit.org/hold pk-metal unhold
HostInMaintenance The Host has metal.platform-kit.org/maintenance Put a host in maintenance
EtcdJoinWaiting Another control plane joins, or etcd is not healthy Wait. If it stays, see etcd unhealthy or quorum lost.
EtcdRiskRefused The removal leaves etcd unsafe Choose an odd size, or set metal.platform-kit.org/ack-etcd-risk. See Scale control planes.
RemovalWaiting Another control plane leaves first Wait.
RolloutRefused The rollout approval does not cover this operation See Rollout paused or plan changed. The machine did not change.
NoReachablePath The BMC does not answer BMC unreachable