Skip to content

Runbook

Operation failed

HostOperation phase
Failed. The condition Executed=False has the reason StepFailed.
Claim
BLOCKED shows OperationFailed or ReleaseFailed.
Host
BiosConverged=False or FirmwareConverged=False with OperationFailed or ConvergenceFailed.
Alert
PkMetalOperationFailed.

The operation stopped at the failed step. Steps before it stay done. The operator proposes nothing for the plan until a person acts.

  1. Read the note line under the OPERATION table.

    Terminal window
    pk-metal status
  2. Find the step that failed and its message.

    Terminal window
    kubectl -n pk-metal describe hostoperation provision-simhw2288v5000397-0f3c9a1e
  3. Find the cause from the step.

Step Common cause Go to
InsertMedia The BMC cannot download the image Media slot busy or missing
AwaitCheckIn, WaitNodeReady The node did not come up in time Node not ready
Drain A PodDisruptionBudget or an emptyDir pod Drain stuck
TalosUpgrade "did not take": Talos went back to the old image Read the node console.
FlashFirmware, ApplyBios The BMC refused the change, or reported success and did not change (ConvergenceFailed) Check the firmware image and the vendor notes.
WaitEtcdHealthy etcd did not become healthy etcd unhealthy or quorum lost
  1. Correct the cause.

  2. Retry the operation. If the operator made it, the operator proposes the same plan again.

    Terminal window
    pk-metal retry pk-metal/provision-simhw2288v5000397-0f3c9a1e
  3. Approve the new proposal.

    Terminal window
    pk-metal approve

The new operation is Succeeded.

To stop new proposals while you look, hold the claim with pk-metal hold. Then follow Collect diagnostics.